Showing 145–160 of 2013 results
-

REQUEST A QUOTE
- Power Rating: 1.5 HP (1.1 kW)
- Input Supply: 3-phase, 380–480 V AC ±10%, 50/60 Hz
- Output Current: 3.3 A (Nominal)
- Frequency Range: 0 to 500 Hz
- Overload Capacity: 150% for 60 seconds (every 10 minutes)
- Control Method: Scalar (V/Hz) control
- Enclosure Rating: IP20 (Cabinet or indoor wall mount)
- Dimensions (HxWxD): 142 mm x 70 mm x 151 mm (approx. 1.0 kg)
ACS150-03E-03A3-4 ABB Variable Frequency Drive.
-

REQUEST A QUOTE
- Power Rating: 3 kW (approx. 4 HP)
- Output Current: 7.3 A max nominal output
- Input Voltage: 380V to 480V AC, 3-phase, 50/60 Hz
- Enclosure Rating: IP20 (suitable for control cabinet mounting)
- Overload Capacity: 150% for 60 seconds every 10 minutes
- Integrated Hardware: Built-in LCD keypad, speed potentiometer, and brake chopper
- Control Connectivity: 1 analog input, 5 digital inputs, and 1 relay output
ACS150-03E-07A3-4 ABB Variable Frequency Drive.
-

REQUEST A QUOTE
- Power Rating: 4 kW (5 HP)
- Output Current: 8.8 A
- Input Voltage: Three-phase 380 V to 480 V AC
- Output Frequency: 0 to 500 Hz
- Frame Size: R1
- Enclosure Rating: IP20
- Control Interface: Integrated user keypad and potentiometer
- I/O Capabilities: 5 digital inputs, built-in braking chopper, and pre-defined application macros
ACS150-03E-08A8-4 ABB Variable Frequency Drive.
-

REQUEST A QUOTE
- Product ID / Type Designation: 3AUA0000039625 / ACS310-03E-01A3-4
- Rated Motor Power: 0.37 kW (0.5 HP)
- Input Voltage: 380–480 V AC, 3-phase
- Output Current: 1.3 A
- Output Frequency: 0 to 500 Hz
- Control Type: Scalar (V/f) control
- Overload Capacity: 110% for 60 seconds
- Enclosure Rating: IP20 (Must be wall-mounted in a clean environment or cubicle-mounted)
- Frame Size: R0
- Digital Inputs: 5
- Analog Inputs: 2 (configurable)
- Analog Outputs: 1
- Relay Outputs: 1
- Embedded Communication: Modbus RTU (via EIA-485 interface)
- Pump & Fan Control (PFC): Built-in macros to alternate and control multiple pumps or fans based on system demand.
- Application Functions: Integrated PID controllers, sleep mode, energy optimizer, and specialized pump cleaning/maintenance functions.
- Integrated EMC Filter: Includes a built-in C2 EMC filter for the second environment.
- Net Weight: 1.1 kg
- Mounting Type: 35mm DIN rail or wall-mounted via rear screw holes
ACS310-03E-01A3-4 ABB Variable Frequency Drive.
-

REQUEST A QUOTE
- Power Rating: 0.55 kW / 0.75 HP
- Input Voltage: 380 V to 480 V AC (3-Phase)
- Output Current: 2.1 A
- Enclosure Rating: IP20
- Application Focus: Optimized for centrifugal loads with dedicated features like multi-pump control, pipe cleaning, and energy-efficiency calculators.
- Application: Ideal for HVAC and industrial pump/fan systems.
- Features: Built-in Modbus RTU interface, coated boards for robustness, and uniform dimensions for clean cabinet mounting.
ACS310-03E-02A1-4 ABB Variable Frequency Drive.
-

REQUEST A QUOTE
- Rated Output Power: 0.75 kW (1 HP)
- Output Current: 2.6 A
- Input Voltage: 380 to 480 V AC, 3-phase, 50/60 Hz
- Output Frequency: 0 to 500 Hz
- Enclosure Rating: IP20 (cabinet or wall mount)
- Frame Size: R1
- Dimensions: 169 mm H (239 mm incl. clamps) x 70 mm W x 143 mm D
- Net Weight: Approx. 1.1 to 1.3 kg
ACS310-03E-02A6-4 ABB Variable Frequency Drive.
-

REQUEST A QUOTE
- Power Rating: 1.1 kW / 1.5 HP.
- Output Frequency: 0 to 500 Hz.
- Motor Control: Scalar control (V/f).
- Enclosure Rating: IP20 (open type, requiring a clean panel/cubicle environment).
- Built-in I/O: 5 digital inputs, 2 analog inputs, 1 digital output, 1 analog output, and 1 relay output.
- Communication: Embedded Modbus EIA-485 interface.
- Braking: No integrated dynamic braking chopper.
ACS310-03E-03A6-4 ABB Variable Frequency Drive.
-

REQUEST A QUOTE
- Power Rating: 1.5 kW (2 HP) for pump/fan loads
- Input Voltage: 380–480V, 3-Phase (±10%) at 50/60 Hz
- Output Current: 4.5 A
- Enclosure Rating: IP20 (requires a clean cabinet or wall environment)
- Frame Size: R1 (Dimensions: approx. 239 x 70 x 162 mm; 1.3 kg)
- Control Method: Scalar (V/f) control
- EMC Filter: Integrated C3 (Industrial) filter
- Braking Chopper: None (not suitable for high-inertia braking requirements)
- Pump and Fan Control (PFC): Allows a single drive to control multiple pumps or fans in parallel to match shifting system demands.
- Dedicated Macros: Includes embedded software routines like pump cleaning (to remove debris from impellers) and PID sleep/wake modes to conserve energy.
- Control UI: Shipped without a keypad by default; it requires an optional basic or assistant control panel for physical programming. It can also be managed via Modbus-RTU or PC software.
ACS310-03E-04A5-4 ABB Variable Frequency Drive.
-

REQUEST A QUOTE
- Rated Output Power: 2.2 kW (3 HP)
- Output Current: 6.2 A
- Input Voltage: 380 to 480 V AC, 3-phase, 50/60 Hz
- Output Frequency: 0 to 500 Hz
- Motor Control: Scalar control (V/f), optimized for variable torque (pumps and fans)
- Enclosure Rating: IP20 (cabinet or wall mount)
- Frame Size: R1
- Communication: Embedded Modbus EIA-485 interface
ACS310-03E-06A2-4 ABB Variable Frequency Drive.
-

REQUEST A QUOTE
- Analog Inputs: 8 differential, independently configurable channels supporting both voltage and current signals.
- Voltage: ±15V, ±10V, ±5V, ±1V, ±500mV, ±150mV, 0–15V, 0–10V, 0–5V, 0–1V, 0–500mV, 0–150mV.
- Current: ±20 mA, 4–20 mA, 0–20 mA.
- Communication Interfaces: RS-485 and Micro USB.
- Supported Protocols: Modbus/RTU and ASCII commands.
- Resolution & Sampling: 16-bit resolution with a combined sampling rate of 100 samples/second.
- Isolation Protection: 3,000 VDC electrical isolation.
- Noise & Surge Immunity: 4 kV surge protection (power), 4 kV Electrical Fast Transient (EFT), and 8 kV Electrostatic Discharge (ESD) protection.
- Power Supply: Accepts a wide unregulated input voltage range from 10 to 48 VDC.
- Operating Temperature: Built for extreme environments, operating between -40°C and 85°C (-40°F to 185°F).
ADAM-4117 ADVANTECH Analog Input Module.
-

REQUEST A QUOTE
- I/O Distribution: 12-channel Digital Input (DI), 2-channel Digital Output (DO), 2-channel Counter
- Power Requirements: 10 to 30 VDC input range (2W @ 24V DC typical consumption)
- Isolation Protection: 2,000 VDC galvanic isolation voltage
- Physical Interfaces: 1 x RJ45 LAN port, 1 x 13-pin plug-in terminal, 1 x 9-pin plug-in terminal
- Operating Temperature: -40°C to 70°C (-40°F to 158°F)
- Digital Input Channels: Features 12 isolated channels supporting both dry contacts (Logic 0: close to GND, Logic 1: open) and wet contacts (Logic 0: 0~3 VDC, Logic 1: 10~30 VDC).
- Counter & Frequency Modes: The 2 counter channels can process inputs up to 4.5 kHz. They can store or discard values upon system power-off and track frequencies from 0.2 Hz to 4500 Hz.
- Digital Output Channels: 2 sink-type channels supporting up to 30 VDC and a maximum load of 100 mA per channel. They natively support 5 kHz pulse outputs.
- Protocol Diversity: Integrates with common SCADA and IoT software through Modbus/TCP, MQTT (with TLS encryption), SNMP, RESTful APIs, UDP, and ASCII commands.
- Edge Intelligence: Employs Peer-to-Peer behavior to link I/O channels across networks without an intervening PLC, alongside a built-in web server for XML and HTML5 dashboards.
- Features Include: Input Voltage: 10~30 VDC; Output Voltage: 0~30 VDC; Sink Current: 100 mA max./channel; Connectors: 1 x RJ45, 1 x…
ADAM-6051 ADVANTECH Ethernet Digital I/O Module.
-

REQUEST A QUOTE
- Digital Inputs: 6 isolated channels supporting dry contacts (logic 0: close to GND, logic 1: open) and wet contacts (logic 1: 10~30 VDC).
- Relay Outputs: 6 Form A power relay channels rated for heavy-duty switching up to 3 A @ 30 VDC and 5 A @ 250 VAC.
- Counter/Encoder: Built-in counter capability with a maximum input frequency of 3 kHz.
- Protocols: Native support for Modbus/TCP, MQTT, SNMP, HTTP, UDP, TCP/IP, and ASCII commands.
- Isolation Protection: 2,000 VDC isolation voltage to safeguard internal electronics against high-energy field noise.
- Environment: Designed for harsh conditions with a rugged form factor operating between -40°C and 70°C.
- Power Supply: Accepts a wide input voltage range of 10~30 VDC.
ADAM-6066 ADVANTECH Ethernet Relay Output Module.
-

REQUEST A QUOTE
- Channels: 15 total channels — 7 digital inputs and 8 digital outputs (Note: Some updated variants like the ADAM-4050-F list an 8 DI / 8 DO configuration).
- Digital Input: Wet contact interface.
- Digital Output: Open-collector transistor switches with a voltage rating of 0 to 30 VDC.
- Communication Interface: RS-485 via 2 x 10-pin plug-in screw terminals.
- Supported Protocols: Modbus/RTU and standard ASCII commands.
- Data Transfer Rate: Up to 115.2 Kbps.
- Power Requirements: 10 to 30 VDC (typical power consumption of 0.18W @ 24 VDC).
- Operating Temperature: -10 to 70 °C (14 to 158 °F).
- Mounting options: DIN-rail or panel mounting.
- Digital Inputs: Primarily used to determine the live state of limit switches, safety switches, or remote digital sensor signals.
ADVANTECH ADAM-4050 Remote Digital I/O Module (ADAM-4000 Series).
-

REQUEST A QUOTE
- Signal Conversion: Converts RS-232 to balanced RS-422 or RS-485 signals.
- Electrical Isolation: Features 3,000 VDC isolation protection to safeguard equipment against ground loops and electrical surges.
- Extended Range: Extends data communication signals up to 1.2 km (4,000 feet), well beyond the standard RS-232 limit.
- Baud Rate: Supports transmission speeds from 1200 bps to 115.2 kbps with automatic baud rate detection.
- Physical Connectors: Equipped with 1 x DB9 female connector (RS-232 side) and 1 x 10-pin plug-in screw terminal (RS-422/485 side).
- Power Supply: Operates on an external input voltage of 10 to 30 VDC.
- Mounting Options: Built with a rugged, compact ABS housing designed for standard DIN-rail or panel mounting inside control cabinets.
ADVANTECH ADAM-4520 RS-232 to RS-422/485 Converter (ADAM-4000).
-

REQUEST A QUOTE
- Input Interface: USB V1.1 (Type B female connector)
- Output Interfaces: 1 x RS-232/422/485 (DB9 female and 10-pin screw terminal)
- Isolation Voltage: 3,000 VDC (Protects the host PC from power surges)
- Baud Rate Speed: 300 bps to 115.2 Kbps
- Power Source: Fully bus-powered via USB (No external power supply required)
- Power Consumption: 1.5 W @ 5 VDC
- Operating Temp: -10°C to 70°C (14°F to 158°F)
- Mounting Options: DIN-rail, panel, wall, or piggyback stack mounting
- No IRQ Conflicts: Because it interfaces through USB, the module does not consume any additional hardware IRQs or traditional system I/O memory addresses.
ADVANTECH ADAM-4561 USB-to-Serial Converter (ADAM).
-

REQUEST A QUOTE
- Digital Inputs: 12 Channels
- Digital Outputs: 6 Channels
- Operating Power: 10 to 30 VDC
- Isolation Voltage: 2,000 VDC
- Operating Temp: -40°C to 70°C (-40°F to 158°F)
- Physical Interface: 1x RJ45 Ethernet
- Multi-Protocol Support: Communicates seamlessly via standard automation and modern IoT profiles, including Modbus TCP, MQTT (with TLS safety), SNMP, RESTful APIs, and ASCII commands.
- Graphic Condition Logic (GCL): Built-in algorithmic engine allowing users to program simple local control rules directly inside the module, creating standalone automated behaviors.
- Cloud Connectivity: Direct telemetry streams to cloud ecosystems such as Microsoft Azure.
- Reliability Systems: Integrated hardware and communication watchdog timers automatically reboot or safe-state the network stack in the event of an edge system crash.
ADVANTECH ADAM-6050 Ethernet Remote I/O Module (ADAM-6000).