- Rated Measuring Voltage: 3×350 to 580 V AC, 50/60 Hz
- Output Contacts: 2 c/o (DPDT) rated at 250 V / 4 A
- Adjustable Off-Delay Time: 0.1 to 30 seconds
- Power Supply: Powered directly via the measuring circuit (No external power required)
- Mounting Format: Standard DIN Rail installation
- Operating Temperature: -25°C to +60°C
- Safety Approvals: GL, UL (Suitable for industrial & railway applications)
- Overvoltage & Undervoltage: Features adjustable threshold values.
- Phase Failure Detection: Instantaneous trip during the loss of any operational phase.
- Phase Unbalance / Imbalance: Protects motors against thermal loads caused by asymmetrical supply networks.
ABB CM-MPN.52S 1SVR750487R8300 Three-Phase Monitoring Relay (CM Series).
-

REQUEST A QUOTE
- Catalog / Order Number: 1SVR730884R3300
- Measuring & Supply Voltage (L-L): 300 to 500 V AC, 50/60 Hz
- Output Contacts: 2 c/o (SPDT / DPDT) relays rated at 250 V / 4 A
- Tripping Delay Range: Adjustable from instantaneous (0 s) up to 30 s
- Connection Technology: Double-chamber cage screw terminals
- Mechanical Life: > 10 million operations
- Environmental Protection: IP20 (Housing) / IP40 (Front panel face)
- Operating Temperature Range: -25°C to +60°C
- Physical Dimensions: 22.5 × 85.6 × 103.7 mm (W × H × D)
- Over- and Undervoltage Monitoring: Detects when phase voltage exceeds or drops below safe, custom-configured constraints.
ABB CM-MPS.41S Three-Phase Monitoring Relay (CM Series).
-

REQUEST A QUOTE
- Catalog / Part Number: CM-PAS.41S / 1SVR730774R3300
- Measuring Voltage Range (L-L): 300 to 500 V AC (50/60 Hz)
- Monitored Parameters: Phase Failure, Phase Sequence, Phase Unbalance (Asymmetry)
- Output Contacts: 2 c/o (DPDT / Double Pole Double Throw) contacts
- Output Contact Rating: 250 V AC / 4 A (Resistive / AC-12)
- Tripping Time Delay: Adjustable ON-delay (0 s or 0.1 to 30 s)
- Response Time: < 100 ms on fault detection
- Terminal Connection Type: Screw Technology (Double-chamber cage connection terminals)
- Mounting Format: 35 mm DIN Rail (Top hat rail according to IEC/EN 60715)
- Operating Temperature: -25 °C to +60 °C (-13 °F to +140 °F)
ABB CM-PAS.41S Three-Phase Monitoring Relay (CM Series).
-

REQUEST A QUOTE
- Catalog Number / Product ID: 1SVR550882R9500
- UPC / EAN: 4013614348136
- Measuring & Control Supply Voltage: 380–440 V AC (L₁, L₂, L₃ Line-to-Line, 50/60 Hz)
- Output Type: 1 Normally Open (N/O) contact, working on the closed-circuit principle
- Contact Rating: 250 V / 4 A
- Fixed Trip Threshold: Phase failure occurs when measuring voltage drops below 60% of rated voltage
- Timing Parameters: 500 ms start-up delay / 150 ms tripping delay
- Terminal / Mounting Type: Screw terminals; Snap-on mounting for standard DIN Rail (TH35)
- Status Indicators: Yellow LED for Relay Status (R)
- Compliance / Standards: UL 508, CAN/CSA C22.2 No.14, IEC/EN 61000-6-2/3, RoHS
ABB CM-PBE 3×380-440VAC Three-Phase Monitoring Relay (CM Series).
-

REQUEST A QUOTE
- Phase Failure (Phase Loss): Instantly detects if one of the three phases goes completely dead or falls below fixed operational thresholds, preventing motors from "single-phasing" (which causes catastrophic winding burnouts).
- Phase Sequence: Ensures that the physical phase rotation matches the expected sequence (L1-L2-L3). If the rotation is reversed, the relay trips to prevent industrial equipment—like motors, pumps, and compressors—from spinning backwards and destroying themselves.
- Metric / Parameter: Specification Details
- Product ID (Standard): 1SVR550824R9100
- Frequency Range: 50 / 60 Hz
- Output Type: 1 c/o (SPDT / Changeover) contact operating on the closed-circuit principle
- Contact Rating: Maximum 250 V / 4 A
- Time Delay Response: ≈ 500 ms start-up/fault delay (fixed thresholds)
- Environmental Temperature: -20°C to +60°C (operational)
- Physical Dimensions: 22.5 mm (W) x 78 mm (H) x 78.5 mm (D)
ABB CM-PFE Three-Phase Monitoring Relay (CM Series).
-

REQUEST A QUOTE
- Frequency Range: 50 / 60 Hz
- Output Contacts: 2 c/o (SPDT changeover)
- Contact Rating: 250 V / 4 A
- Monitored Parameters: Phase Failure & Phase Sequence
- Response Time Delay: 500 ms
- Terminal Connection: Screw Terminals
- Mounting Type: DIN Rail Mountable
- Enclosure Rating: IP50 (Housing) / IP20 (Terminals)
- Self-Powered Efficiency: The relay does not require an external power supply; it is directly powered from the L1-L2-L3 measuring voltage lines.
- Phase Sequence Monitoring: Ensures that the phases are in the correct sequence (L1-L2-L3). If a sequence is inverted (which can cause three-phase motors to rotate backwards), the relay de-energizes.
ABB CM-PFS.S Three-Phase Monitoring Relay (CM Series).
-

REQUEST A QUOTE
- Phase Loss Monitoring: Protects downstream equipment (such as three-phase motors) from running on a missing phase, which causes severe overheating and immediate winding damage.
- Overvoltage & Undervoltage Protection: Monitors the mains voltage to ensure it stays within a safe, fixed window. If the voltage swings outside the nominal thresholds, it trips to prevent insulation breakdown or equipment brownouts.
- Interrupted Neutral Monitoring: Ensures that single-phase loads tied to the neutral wire are protected from unpredictable voltage fluctuations or floating neutrals.
- Manufacturer: ABB
- Measuring & Supply Voltage: Phase-to-Neutral (L-N):
- Output Configuration: 1 N/O (Normally Open) output contact
- Output Contact Rating: 250 V / 4 A (AC-12 resistive load)
- Threshold Adjustments: Fixed (Non-adjustable windows)
- Connection Capacity: Rigid / Flexible: 2x 18-16 AWG
- Tightening Torque: 7.08 in⋅lb (0.8 N⋅m)
ABB CM-PVE 185-265VAC Three-Phase Monitoring Relay (CM Series).
-

REQUEST A QUOTE
- Product ID / Code: 1SVR550871R9500
- Measuring / Supply Range: 320–460 V AC (L₁-L₂-L₃)
- Rated Frequency: 50 / 60 Hz
- Output Contact: 1 N/O (Normally Open)
- Contact Rating: 250 V / 4 A
- Response Time: 80 ms
- Hysteresis: 5%
- Housing Width: 22.5 mm
- Connection Type: Screw Terminals
- Phase Loss Detection: Instantly drops the output relay if any of the three phases fail completely.
ABB CM-PVE 3×320-460VAC Three-Phase Monitoring Relay (CM Series).
-

REQUEST A QUOTE
- Measuring & Supply Voltage: 3×300 to 500 V AC (50/60 Hz), self-powered from line
- Output Type: 2 c/o (DPDT / Change-over) contacts
- Contact Rating: 250 V AC / 4 A
- Tripping Delay Time: Adjustable from 0 s (instantaneous) up to 30 s
- Delay Behavior: Selectable ON-delay or OFF-delay configuration
- Terminal Connection: Screw terminals with double-chamber cage clamps
- Mounting Style: Standard 35 mm DIN Rail
- Protection Degree: Housing: IP50 | Terminals: IP20
- Approvals / Standards: CE, cULus, EAC, CCC, IEC 60255-27, Railway Approved
- R (Yellow): Indicates the state of the output relay contacts.
ABB CM-PVS.41S Three-Phase Monitoring Relay (CM Series).
-

REQUEST A QUOTE
- ABB Article ID / EAN: 1SFA619100R1112 / 7320500550717
- Mounting Hole Diameter: 22.3 mm (Standard 22 mm panel cutout)
- Physical Dimensions: 30 mm × 30 mm × 55 mm (W × H × D)
- Net Weight: 0.018 kg (0.63 oz)
- Contact Configuration: 1 NO (Normally Open), 0 NC
- Operating Voltage: 24 V AC/DC (for the integrated green LED)
- Ingress Protection: IP20 (Terminals), IP66 / IP67 / IP69K (Front face)
- NEMA Enclosure Ratings: NEMA 1, 3R, 4, 4X, 12, 13
- Mechanical Durability: 500,000 operations (0.5 million cycles)
- Terminal Connections: Threaded screw clamp terminals
ABB CP1-11G-10 Illuminated Pushbutton Switch (Compact Range).
-

REQUEST A QUOTE
- Manufacturer: ABB (Asea Brown Boveri)
- Global Order Code / SKU: 1SVR405633R1100
- Relay Family Range: CR-MX (Pluggable Miniature Range)
- Contact Configuration: 4 c/o (SPDT) (4 Change-Over / Single Pole Double Throw contacts)
- Rated Output / Load Current: 5 A at 250 V AC (Note: Some manufacturing sheets list peak limits up to 7 A)
- Physical Pin Count: 14 Pins (Flat blade style plug-in design)
- Diagnostics Sub-Function: Integrated LED Indicator (Lights up when the coil is energized for easy troubleshooting)
- Environmental Compliance: RoHS Directive 2011/65/EU
- Visual Status Monitoring: The built-in LED provides immediate physical confirmation of control loop status without requiring manual multimeter probing.
- Modular Assembly: Designed to sit inside matching standard 14-pin DIN-rail mount sockets. It supports pluggable function modules (such as RC elements or varistor surge suppressors), mechanical holders, and identification markers.
ABB CR-MX024DC4L DC24V Pluggable Interface Relay (CR-M Series).
-

REQUEST A QUOTE
- Channels: 8 digital inputs, individually galvanic isolated
- Input Signal Thresholds: "0" Signal: 0–50 V a.c., 0–40 V d.c.
- Input Impedance: 21 kΩ (a.c.) / 134 kΩ (d.c.)
- Filtering & Delays: 6 ms analog filter; Selectable digital filter times (2, 4, 8, 16 ms)
- Analog Filter On/Off Delay: 5 / 28 ms
- Power Dissipation: Typically 2.8 W
- Modulebus Consumption: 50 mA @ +5 V Modulebus; 0 mA @ +24 V
- Max Cable Length: 200 m / 218.7 yds (a.c.), 600 m / 656.1 yds (d.c.)
- Physical Weight: 0.2 kg / 0.44 lbs
- Individual Galvanic Isolation: Every input channel is isolated from the others, providing superior fault isolation and protection for your central control hardware.
ABB DI821 3BSE008550R1 Digital Input Module (S800 I/O).
-

REQUEST A QUOTE
- Network Protocol: EtherNet/IP (supports both standard ABB drives profiles and ODVA AC/DC drives profiles).
- Physical Interface: Two RJ-45 Ethernet ports utilizing twisted-pair media.
- Network Topologies: Supports Star, Daisy Chain, and Ring topologies.
- Enclosure Rating: IP20 / NEMA 1 equivalent (designed for indoor/cabinet installation).
- Embedded Switch for DLR: Features an integrated network switch that natively supports Device Level Ring (DLR). This allows you to construct a redundant, fault-tolerant Ethernet ring network without purchasing or installing an expensive external DLR switch.
- Rockwell/Allen-Bradley Ecosystem Optimization: Highly optimized for easy integration into Rockwell Automation environments (Studio 5000/Logix platforms) using downloadable Add-On Instructions (AOI) and electronic data sheets (EDS).
- Drive Composer Pro Support: Fully compatible with ABB's PC-based Drive Composer Pro Software, allowing commissioning engineers to perform startup, configuration, and monitoring directly over the Ethernet network.
- Primary Protocols: EtherNet/IP exclusively
- Hardware Performance: Modern chipset, optimized Requested Packet Interval (RPI) processing
ABB FEIP-21 EtherNet/IP Fieldbus Adapter (ABB Drives).
-

- Brand: ABB
- Model: FSCA-01
- Series: F-Series Fieldbus Adapter
- Network interface: RS-485
- Protocol: Modbus RTU
- Function: Connects ABB drives to a serial fieldbus
- Supported functions: Single and multiple Modbus register read/write functions
- Compatible drives: ACS580, ACH580, ACQ580, ACS880, DCS880 and DCT880
- Typical profile: ABB Drives Enhanced profile supported
-

REQUEST A QUOTE
- Model / Part Number: MS132-32 / 1SAM350000R1015
- Current Setting Range: 25.0 to 32.0 A
- Trip Class: Class 10
- Number of Poles: 3P (3-Pole)
- Rated Operational Voltage: Up to 690 VAC
- Protection Degree: IP20 (Housing) / IP10 (Terminals)
- Operating Temperature: -25°C to +70°C
- Advanced Fault Indication: Unlike standard models (like the MS116), the MS132 features a separate, visual trip window that distinguishes between an overload trip and a short-circuit trip at a glance.
- Integrated Disconnect Function: Provides a reliable safety isolation mechanism that fully cuts off power downstream when switched to the "OFF" position.
- Lockable Rotary Handle: Built-in mechanism allows the handle to be padlocked directly in the "OFF" position for Lockout/Tagout (LOTO) safety compliance.
ABB MS132-32 Manual Motor Starter (MPCB) (MS132).
-

- Manufacturer: ABB
- Model / Part Number: NPBA-12
- Product Part Number: 64348221 (or alternate manufacturing IDs like 64248677)
- Network Protocol: PROFIBUS DP
- Data Transfer Speed: Up to 12 Mbps
- Power Requirement: 24V DC (Draws about 70 mA)
- Degree of Protection: IP20 (Safe to touch, but not waterproof)
- Mounting: Snaps onto a standard DIN rail