Jungui Automation

PLC & Controllers

Find the right controller or I/O component

Match the complete manufacturer part number before choosing a controller, input/output module or bus coupler. Products in the same family can differ in power supply, signal type, channel count and communication interface.

Analog inputs: compare signal ranges and resolution, such as the IDEC FC6A-PJ2A cartridge.

Digital inputs: check input voltage and terminal-system requirements, such as the SIEMENS 6ES7131-4BD01-0AB0.

Motion controllers: confirm local I/O and required motion-network capabilities, such as the INOVANCE AM521-0808TN.

These examples describe different component roles and are not interchangeable replacements.

PLC & Controllers: Model Directory. Open a model to view its technical specifications.

IDEC FC6A-C24K1CE PLC CPU Module (MicroSmart FC6A) | IDEC FC6A-C16R1AE PLC CPU Module (MicroSmart FC6A) | IDEC FC4A-N32B3 Digital Input Module (MicroSmart FC4A) | IDEC FC4A-C16R2 PLC CPU Module (MicroSmart FC4A) | SCHNEIDER 140CRA93200 Remote I/O Adapter (Modicon Quantum) | SCHNEIDER 140CRA93100 Remote I/O Adapter (Modicon Quantum) | SCHNEIDER 140CPU53414A CPU Module (Modicon Quantum) | SCHNEIDER 140AVI03000 Analog Input Module (Modicon Quantum) | SCHNEIDER 140ACO02000 Analog Output Module (Modicon Quantum) | SCHNEIDER 140ACI04000 Analog Input Module (Modicon Quantum)

Showing 257–272 of 294 results

  • AFP0RC14RS PLC Module For PANASONIC

    PANASONIC AFP0RC14RS PLC CPU Unit (FP0R)

    REQUEST A QUOTE

    • Control Unit Type: FP0R-C14RS
    • I/O Configuration: 14 I/O points total, consisting of 8 Inputs (24VDC, compatible with both NPN/PNP sink or source) and 6 Outputs (Relay contacts, 2A).
    • Memory Capacity: 16k steps of program memory alongside a large data register allocation.
    • Supply Voltage: 24V DC.
    • Connectivity & Programming Ports: Features a built-in Mini USB port and an RS-232C port for tool programming and communication flexibility.
    • Termination & Mounting: Uses standard screw terminal blocks for secure wiring and mounts directly onto a standard DIN rail.

    PANASONIC AFP0RC14RS PLC CPU Unit (FP0R).

  • PANASONIC AFPX-COM3 Communication Cassette (FP-X)

    PANASONIC AFPX-COM3 Communication Cassette (FP-X)

    REQUEST A QUOTE

    • Series Compatibility: Panasonic FP-X / FP-XH PLC Series
    • Number of Channels: 1 Channel
    • Interface Types: RS-485 or RS-422 (Selectable via hardware/software switches)
    • Insulation Type: Fully insulated port (protects the PLC from voltage spikes and ground loops)
    • Maximum Baud Rate: Up to 115 kbps
    • Wiring Termination: M3 Screw terminals
    • Mounting Type: Direct plug-in slot on the FP-X controller body
    • Space-Saving Expansion: It mounts directly onto the front face of the PLC, preserving valuable control panel space.
    • Multi-Drop Networking: Ideal for configuring Modbus-RTU, MEWTOCOL, or general-purpose serial communication networks to connect HMIs, variable frequency drives (VFDs), sensors, or other PLCs.
    • Electrical Protection: Internal electrical insulation ensures stable communications in high-interference industrial environments.

    PANASONIC AFPX-COM3 Communication Cassette (FP-X).

  • PCA-6751REV B202-1 ADVANTECH Single Board Computer

    PCA-6751REV B202-1 ADVANTECH Single Board Computer

    REQUEST A QUOTE

    • Processor: Integrated, on-board Intel Pentium MMX CPU running at 266 MHz.
    • Chipset: Intel 430TX (PCIset TX Triton II).
    • Memory: Two 144-pin SDR SO-DIMM sockets supporting up to 256 MB SDRAM.
    • On-board Storage: CompactFlash SSD solution slot.
    • Display Controller: C&T 69000 VGA/LCD controller with integrated PCI SVGA support.
    • Networking: 10/100 Mbps Ethernet RJ-45 connection.
    • Expansion Slots: 1x 16-bit ISA bus interface and 1x PC/104 expansion interface.
    • System Protection: On-board Watchdog Timer capable of triggering a system reset or IRQ 11.
    • BIOS: AWARD 256 Kbit Flash BIOS featuring Plug & Play, APM 1.2, and Ethernet Boot ROM capability.

    PCA-6751REV B202-1 ADVANTECH Single Board Computer.

  • PEPPERL+FUCHS IC-KP2-1HB17-2V1D 200876 Module

    PEPPERL+FUCHS IC-KP2-1HB17-2V1D 200876 RFID Control Interface (IDENTControl)

    REQUEST A QUOTE

    • Device Type: Control interface unit / RFID evaluation unit.
    • Channels & Connections: Supports up to 2 channels/ports. It can connect up to 2 read/write heads, or alternatively, 1 read/write head and 1 trigger sensor.
    • Protocols: Built-in 2-port Ethernet switch supporting TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP.
    • Electrical: Operating voltage of 20 to 30 V DC (PELV), with a power consumption of 3.5 W (excluding heads).
    • Physical Connectors: Heavy-duty M12 plug connections for Ethernet, power, and read/write heads. Includes an M4 grounding screw.
    • Housing & Protection: Rugged, powder-coated aluminum housing measuring 42mm x 62mm x 137mm with an IP67 environment protection rating.

    PEPPERL+FUCHS IC-KP2-1HB17-2V1D 200876 RFID Control Interface (IDENTControl).

  • PEPPERL+FUCHS IC-KP2-2HB17-2V1D RFID Evaluation Unit (IDENTControl)

    PEPPERL+FUCHS IC-KP2-2HB17-2V1D RFID Evaluation Unit (IDENTControl)

    REQUEST A QUOTE

    • Channels/Ports: 2 channels (supports up to 2 read/write heads, or 1 head and 1 trigger sensor).
    • Network Interfaces: Multi-protocol Ethernet support including EtherNet/IP, PROFINET IO, Modbus TCP, and TCP/IP.
    • Integrated Switch: Features an integrated 2-port switch for network loop-through line topologies.
    • Power Supply: 20 to 30 V DC.
    • Protection Rating: IP67 rugged design.
    • Housing Material: Powder-coated aluminum.
    • Connections: M12 plug connectors for power, Ethernet, and read/write heads.

    PEPPERL+FUCHS IC-KP2-2HB17-2V1D RFID Evaluation Unit (IDENTControl).

  • PILZ 312025 Head Communication Module (PSSuniversal)

    PILZ 312025 Head Communication Module (PSSuniversal)

    REQUEST A QUOTE

    • Product ID / Model Type: 312025 (PSSu H SB DP)
    • Device Function: Head communication module for standard and decentralized safety environments.
    • System Platform Compatibility: Guard PLC / PSS 4000 automation network architectures.
    • Supported Protocols: Integrates both SafetyBUS p and PROFIBUS-DP fieldbus interfaces into a single head unit.
    • Device Type: Slave
    • Protocol Version: DPV0
    • Maximum Transmission Rate: Up to 12 MBit/s (Automatic rate detection supported).
    • Station Address Range: 0 to 126d (Configured via onboard DIP hardware switches).
    • Transmission Rate: 500 kBit/s
    • Transmission Type: Differential two-wire cable

    PILZ 312025 Head Communication Module (PSSuniversal).

  • Pilz 312200 Failsafe Digital I/O Module (PSSu Series)

    Pilz 312200 Failsafe Digital I/O Module (PSSu Series)

    REQUEST A QUOTE

    • Module Type: Failsafe Digital Safety Input Module
    • Digital Inputs: 4 independent safety inputs (I0 to I3), operating at 24 V DC / 6 mA
    • Digital Outputs: 2 test pulse transistor outputs (T0 & T1), rated at 24 V DC / 0.25 A
    • Operating Voltage: 16.8V DC to 30V DC (24 V DC Nominal)
    • Environmental Limits: 0°C to 60°C operating temperature; up to 2000 m permanent operating height
    • Dimensions: 76 mm (H) x 12.6 mm (W) x 60.2 mm (D)
    • Protection Class: IP20 enclosure level protection

    Pilz 312200 Failsafe Digital I/O Module (PSSu Series).

  • Red Lion CUB5B000 Dual Counter Rate Indicator (CUB5 Series)

    Red Lion CUB5B000 Dual Counter Rate Indicator (CUB5 Series)

    REQUEST A QUOTE

    • Manufacturer: Red Lion Controls
    • Display Type: 8-digit LCD with user-selectable red or green backlighting (0.46" / 11.7mm digit height)
    • Input Frequency: Up to 20 kHz max
    • Supply Voltage: 9 to 28 VDC
    • Environmental Protection: NEMA 4X / IP65 front panel (water/dust resistant)
    • Operating Temperature: -35°C to +75°C
    • Counting Modes: Bi-directional counting, up/down control, quadrature sensing, batch counting
    • Dynamic Color Changes: You can program the backlight to automatically switch from green to red (or vice versa) when a specific preset limit is reached.
    • Modular Expansion: Built-in capabilities can be enhanced using plug-in optional cards available from Red Lion:
    • Brand: Red Lion. Part Number # : CUB5B000. SKU #:, 2143103. Dimensions: 1.54 in H x 2.95 in W x 1.71 in D. Frequency Rating: 20 kH…

    Red Lion CUB5B000 Dual Counter Rate Indicator (CUB5 Series).

  • 140ACI04000 PLC Module For SCHNEIDER

    SCHNEIDER 140ACI04000 Analog Input Module (Modicon Quantum)

    REQUEST A QUOTE

    • Channels: 16 channels (differential).
    • Input Ranges: Configurable for 0…20 mA, 4…20 mA, or 0…25 mA current signals.
    • Input Impedance: 250 Ohms.
    • Absolute Accuracy Error: +/- 0.125 % of full scale.
    • Addressing Requirements: Uses 17 input words in the control system architecture.
    • Built-in Protection: Features active broken wire detection when running in the standard 4…20 mA mode.
    • Isolation: Optical isolation between the channel circuitry and the backplane bus (1780 V AC for 60 seconds), allowing safe hot-swapping.
    • Hardware Interface: Connects via a separate Schneider 140XTS00200 removable terminal strip for easier field wiring and drop-in maintenance.
    • Product Description P/N: 140ACI04000 * Description. The Schneider Electric 140ACI04000 is a 16-channel analog current input module…

    SCHNEIDER 140ACI04000 Analog Input Module (Modicon Quantum).

  • 140ACO02000 PLC Module For SCHNEIDER

    SCHNEIDER 140ACO02000 Analog Output Module (Modicon Quantum)

    REQUEST A QUOTE

    • Number of Outputs: 4 analog channels
    • Output Signal Range: 4 to 20 mA (0 to 4096 counts)
    • Resolution: 12-bit bipolar current
    • Addressing Requirement: 4 output words
    • External Loop Voltage: 12 to 30 V DC
    • Maximum Voltage Drop: 30 V @ 20 mA
    • Module Format: Standard Quantum slot footprint
    • Absolute Accuracy Error: ±0.20% of full scale at 25 °C
    • Linearity: ±1 LSB
    • Temperature Drift: ±0.004% of full scale/°C (±0.007% of full scale/°C maximum)

    SCHNEIDER 140ACO02000 Analog Output Module (Modicon Quantum).

  • 140AVI03000 PLC Module For SCHNEIDER

    SCHNEIDER 140AVI03000 Analog Input Module (Modicon Quantum)

    REQUEST A QUOTE

    • Inputs: 8 differential channels.
    • Resolution: 16-bit analog-to-digital conversion.
    • Unipolar Voltage: 0 to 5 V, 0 to 10 V
    • Bipolar Voltage: ±5 V, ±10 V
    • Unipolar/Bipolar Current: 0 to 20 mA, ±20 mA
    • Addressing: Requires 9 input words in the control system architecture.
    • Update Time: 10 ms refresh rate.
    • Isolation: 500 Vrms AC between the channels and the bus; 135 Vrms AC between individual channels.
    • Power Consumption: 2.2 W power dissipation; 280 mA current draw from the bus.
    • Diagnostics: Built-in LED indicators tracking channel status, channel faults, and external faults. It features broken wire detection for 4–20 mA loops.

    SCHNEIDER 140AVI03000 Analog Input Module (Modicon Quantum).

  • 140CPU53414A PLC Module For SCHNEIDER

    SCHNEIDER 140CPU53414A CPU Module (Modicon Quantum)

    REQUEST A QUOTE

    • Processor Type: 80586 (Intel 586 Architecture), 133 MHz Clock Speed
    • Internal Memory: 4 MB SRAM (supports ~2.5 MB to 2.7 MB IEC application memory / 64k words user logic)
    • Logic Solve Time: 0.1 to 0.5 ms per kiloword (ms/k)
    • Programming Software: Concept / Unity Pro
    • Watchdog Timer: 250 ms (software adjustable)
    • Hardware Topology Note: Functionally identical to the non-"A" version. However, for Hot Standby topologies, you must use identical pairs (either two non-"A" or two "A" modules).
    • Built-in Communication Ports: 2 × RS-232 serial ports (9-pin D-shell) utilizing Modbus protocol.
    • Network Module Support: Expansion capability for up to 6 network modules including Modbus Plus, Ethernet, and Multi-Axis Motion options.
    • I/O Capability: Supports up to 64 input and 64 output words locally, with expansion capacity for up to 31 remote I/O drops.
    • Bus Current Requirement: 1.25 A

    SCHNEIDER 140CPU53414A CPU Module (Modicon Quantum).

  • 140CRA93100 PLC Module For SCHNEIDER

    SCHNEIDER 140CRA93100 Remote I/O Adapter (Modicon Quantum)

    REQUEST A QUOTE

    • Product Type: RIO drop adaptor module
    • Range Compatibility: Modicon Quantum automation platform
    • Electrical Connection: 1 female connector F (elbowed) with single cable
    • Cable Requirements: Coaxial 75 Ohm
    • Transmission Rate: 1544 Mbit/s
    • Dynamic Range: 35 dB
    • Isolation Voltage: 500 V DC (coaxial center and ground)
    • Power Dissipation: 3 W (1 channel)
    • Bus Current Requirement: 600 mA (1 channel)
    • Electrostatic Discharge: 8 kV on air, 4 kV contact (conforming to IEC 801-2)

    SCHNEIDER 140CRA93100 Remote I/O Adapter (Modicon Quantum).

  • 140CRA93200 PLC Module For SCHNEIDER

    SCHNEIDER 140CRA93200 Remote I/O Adapter (Modicon Quantum)

    REQUEST A QUOTE

    • Metric: Specification
    • Module Type: RIO Drop Adapter Module
    • Compatibility: Modicon Quantum Automation Platform
    • Transmission Rate: 1,544 Mbit/s
    • Cable Type: 75 Ohm Coaxial Cable
    • Connectors: 2 female F-type elbowed connectors (supports redundant cable setups)
    • Max Expansion Capacity: Up to 27 I/O expansion modules
    • Power Dissipation: 3.8 W across 2 channels
    • Bus Current Requirement: 750 mA across 2 channels
    • Isolation Voltage: 500 V DC between coaxial center and ground

    SCHNEIDER 140CRA93200 Remote I/O Adapter (Modicon Quantum).

  • SEGGER J-LINK PRO JTAG/SWD Debug Probe (J-Link)

    SEGGER J-LINK PRO JTAG/SWD Debug Probe (J-Link)

    REQUEST A QUOTE

    • Download Speed: Outstanding speeds up to 4 MB/s into target RAM.
    • Host Connectivity: Dual-interface supporting both Hi-Speed USB 2.0 and 10/100 Ethernet.
    • Cross-Platform: Out-of-the-box driver and software compatibility with Windows, Linux, and macOS.
    • Target Interface Support: Broad coverage including JTAG, cJTAG, SWD, SWO, and direct SPI flash interfacing.
    • Unlimited Flash Breakpoints: Overcomes hardware breakpoint limitations, allowing you to set as many breakpoints as necessary inside internal or external flash memory.
    • J-Flash: A powerful standalone suite for programming flash memory on Cortex-M/R/A, RX, and RISC-V targets.
    • Ozone: SEGGER’s flagship graphical debugger and performance analyzer for precise instruction tracing and code optimization.
    • Comparison: J-Link PRO vs. J-Link PRO PoE
    • Feature / Variant: J-Link PRO (Standard)
    • Primary Use Case: Universal debug probe for individual long-distance desk setups or remote targets.

    SEGGER J-LINK PRO JTAG/SWD Debug Probe (J-Link).

  • SEW-EURODRIVE DBG60B-01 Controller

    SEW-EURODRIVE DBG60B-01 Operator Keypad (SEW)

    REQUEST A QUOTE

    • Part Number: 1820 403 1 (or 18229150)
    • Interface: 21-key keypad with a multi-line illuminated LCD text display.
    • Power Supply: 24 V DC (powered directly via the inverter interface).
    • Enclosure Rating: IP40 protection class (some variants list IP20).
    • Parameter Copying: You can extract a complete parameter set from an inverter using the COPY TO DBG menu command, move the keypad to a different inverter, and flash it using COPY TO MDX.
    • Manual Motor Control: When within safe visual sight of the application, the Start and Stop keys can be used to manually jog or run the motor.
    • Diagnostics & Fault Reset: Displays specific system fault codes and descriptions. Faults can be cleared manually by navigating to parameter 840 (Reset) and toggling it to "Yes".
    • User Menu Customization: Allows users to map a custom menu containing up to 50 frequently accessed parameters for quick navigation.

    SEW-EURODRIVE DBG60B-01 Operator Keypad (SEW).