Jungui Automation

Communication & Networking

Choosing a communication component

Start with the protocol used by each side of the connection. A serial device server, protocol gateway and fieldbus coupler serve different roles; an Ethernet connector alone does not establish compatibility.

Match the serial interface: RS-232, RS-422 or RS-485.

Check the network protocol and required number of ports.

Confirm the supply voltage, connector arrangement and isolation requirements for the exact model.

For protocol conversion, also browse IoT gateways. For EtherCAT terminal connections, see the BECKHOFF BK1120 bus coupler.

Communication & Networking: Model Directory. Open a model to view its technical specifications.

MOXA NPORT 5232I Serial Device Server (NPort 5232I)

Showing 17–32 of 77 results

  • B&R 5ACPCE.ETH4-00 Ethernet Expansion Card (APC)

    B&R 5ACPCE.ETH4-00 Ethernet Expansion Card (APC)

    REQUEST A QUOTE

    • Quantity of Ports: 4
    • Ethernet Controller: Intel I350
    • Variant/Connector Type: RJ45, shielded
    • Transfer Rate: 10/100/1000 Mbit/s (Gigabit Ethernet)
    • Line Length: Max. 100 meters between two stations
    • B&R ID Code: 0xEC3B
    • Power Consumption: 4 W
    • Diagnostics: Data transfer status via integrated LED status indicators
    • CE / UKCA: Yes
    • UL Listing: cULus E115267 Industrial control equipment

    B&R 5ACPCE.ETH4-00 Ethernet Expansion Card (APC).

  • B&R 5ACPCI.ETH1-01 Ethernet Interface Card (APC)

    B&R 5ACPCI.ETH1-01 Ethernet Interface Card (APC)

    REQUEST A QUOTE

    • Manufacturer: B&R Industrial Automation (ABB)
    • Part Number: 5ACPCI.ETH1-01
    • Product Type: PCI Network Interface Card (Add-on Board)
    • Interfaces: 1x Ethernet Port
    • Transmission Rate: 10/100 Mbit/s
    • Connection Type: Shielded RJ45
    • Form Factor: Half-size PCI card
    • Slot Compatibility: Standard 16-bit PCI slot
    • Voltage Compatibility: Universal (Supports both 3.3 V and 5 V signaling)
    • Power Consumption: Rated at 1.1 A to 1.6 A (depending on system load/revision)

    B&R 5ACPCI.ETH1-01 Ethernet Interface Card (APC).

  • B&R 5ACPCI.MFIO-K01 Fieldbus Interface Card (APC)

    B&R 5ACPCI.MFIO-K01 Fieldbus Interface Card (APC)

    REQUEST A QUOTE

    • Interface Type: Standard PCI expansion card.
    • Supported Protocols: Profibus DP, K-Feldbus (K-Fieldbus), and serial COM communications.
    • Primary Function: Acts as a multi-function input/output (MFIO) and network interface card, allowing industrial control hosts to communicate seamlessly with field level devices and PLCs over legacy and robust industrial networks.

    B&R 5ACPCI.MFIO-K01 Fieldbus Interface Card (APC).

  • B&R 5LS189.6 Link Logic Scanner Module (POWERLINK)

    B&R 5LS189.6 Link Logic Scanner Module (POWERLINK)

    REQUEST A QUOTE

    • Primary Interfaces: 1x Ethernet POWERLINK (V1/V2) interface (operates as a managing or controlled node) and 1x X2X Link master interface.
    • Onboard Memory: Equipped with 1 MB SRAM for Automation Runtime / remanent process variables, and 512 KB FlashPROM.
    • Hardware Form Factor: PCI half-size slot module. It features electrical isolation, a ready relay, and connects via an RJ45 port.
    • Crucial Note: The unit requires two separate terminal blocks (model TB704) for wiring, which must be ordered separately.

    B&R 5LS189.6 Link Logic Scanner Module (POWERLINK).

  • B&R 5LS189.6-1 Logic Scanner Module (POWERLINK)

    B&R 5LS189.6-1 Logic Scanner Module (POWERLINK)

    REQUEST A QUOTE

    • Form Factor: PCI half-size card format.
    • Memory Capacity: 1 MB battery-backed SRAM for remanent data storage (process variables and data objects) along with 512 KB FlashPROM.
    • Power & Protection: 4-Watt power consumption with an IP20 environment protection rating.
    • Additional Hardware: Integrated ready relay and plug-and-play installation support.
    • Accessories Note: Requires two TB704 terminal blocks, which must be ordered separately.

    B&R 5LS189.6-1 Logic Scanner Module (POWERLINK).

  • B&R 5LS189.6-2 Logic Scanner Module (POWERLINK)

    B&R 5LS189.6-2 Logic Scanner Module (POWERLINK)

    REQUEST A QUOTE

    • Primary Interfaces: Features 1x Ethernet POWERLINK interface (operating as a managing or controlled node) and 1x X2X Link master interface.
    • Hardware Format: Built as a standard PCI half-size expansion card designed to plug into B&R Industrial PCs (such as the APC620 or APC910 lines).
    • Memory: Equipped with 1 MB of onboard SRAM dedicated to remanent data, process variables, and data objects.
    • Application: Functions as an automation network processor often used in complex motion control or real-time Ethernet topologies.

    B&R 5LS189.6-2 Logic Scanner Module (POWERLINK).

  • B&R 7IF787.9 Industrial Interface Module

    B&R 7IF787.9 Industrial Interface Module

    • Manufacturer: B&R
    • Model / Part Number: 7IF787.9
    • Module Type: aPCI industrial interface module
    • Host Interface: aPCI slot
    • Electrical Isolation: Galvanically isolated interface
    • Required Terminal Block: TB704
  • BALLUFF BNI004L BNIIOL-310-000-K025 IO-Link Sensor/Actuator Hub

    BALLUFF BNI004L BNIIOL-310-000-K025 IO-Link Sensor/Actuator Hub

    REQUEST A QUOTE

    • Manufacturer: BALLUFF
    • Model / Part Number: BNI004L BNIIOL-310-000-K025
    • Operating Voltage: 18–30.2 V DC
    • Rated Operating Voltage: 24 V DC
    • Protocol: IO-Link 1.0
    • Transfer Rate: COM2, 38.4 kbaud
    • Digital Inputs: 16 × PNP, Type 2
    • Digital Outputs: 16 × PNP
    • Mounting: DIN rail
    • Enclosure Rating: IP20
    • Ambient Temperature: −20 to 50 °C

    BALLUFF BNI004L BNIIOL-310-000-K025 IO-Link Sensor/Actuator Hub. Key specifications include Operating Voltage: 18–30.2 V DC; Rated Operating Voltage: 24 V DC; Protocol: IO-Link 1.0; Transfer Rate: COM2, 38.4 kbaud.

  • BECKHOFF BK9100 Industrial Switch

    BECKHOFF BK9100 Ethernet Bus Coupler (BK Series)

    REQUEST A QUOTE

    • Data Transfer Rates: 10 / 100 Mbit/s (Automatic recognition)
    • Supported Protocols: TwinCAT ADS, Modbus TCP, Beckhoff Real-Time Ethernet
    • Bus Interface: 2 x RJ45 (Internal 2-channel switch)
    • I/O Capacity: 64 standard Bus Terminals (Up to 255 via K-bus extension)
    • Process Image Size: 512 bytes input / 512 bytes output
    • Max Peripheral Signals: 512 Digital I/O or 128 Analog I/O
    • Power Supply: 24 V DC (-15% / +20%)
    • K-Bus Current Supply: 1750 mA
    • Configuration Tool: Via Beckhoff KS2000 software
    • Operating Temp: -25 °C to +60 °C (-13 °F to +140 °F)

    BECKHOFF BK9100 Ethernet Bus Coupler (BK Series).

  • BECKHOFF EK1100-0000 EtherCAT Coupler

    BECKHOFF EK1100-0000 EtherCAT Coupler

    • Manufacturer: BECKHOFF
    • Model / Part Number: EK1100-0000
    • Function: Converts EtherCAT telegrams from 100BASE-TX to E-bus signals
    • Data Rate: 100 Mbit/s full duplex
    • Bus Interfaces: 2 x RJ45
    • Supply Voltage: 24 VDC, -15%/+20%
    • E-Bus Supply: 5 V, 2 A maximum
    • Supported Topologies: Line, star and tree
    • Dimensions: 44 x 100 x 68 mm
    • Operating Temperature: -25 to +60 °C
    • Degree of Protection: IP20
  • BECKHOFF EL6631-0010 PROFINET Controller Terminal

    BECKHOFF EL6631-0010 PROFINET Controller Terminal

    • Manufacturer: BECKHOFF
    • Model / Part Number: EL6631-0010
    • Fieldbus Function: PROFINET RT controller
    • Ethernet Ports: 2-port switched interface
    • System Bus: EtherCAT E-bus
    • Mounting: DIN rail terminal assembly
  • CAREL PCO100TLN0 tLAN Communication Card

    CAREL PCO100TLN0 tLAN Communication Card

    • Manufacturer: CAREL
    • Model / Part Number: PCO100TLN0
    • Network Interface: tLAN serial network
    • Network Connectors: 2
    • Maximum Network Devices: 5
    • Operating Temperature: -10 to 60 °C
    • Recommended Cable: Shielded twisted-pair cable, AWG 20/22
  • DANFOSS 084B8565 EKA179A Communication Card

    DANFOSS 084B8565 EKA179A Data Communication Module (EKA 179 Series)

    REQUEST A QUOTE

    • Module Type: Communication Module / LON Card
    • Hardware Interface: RS-485 physical connection layer
    • Network Protocol: LON (Local Operating Network)
    • Device Compatibility: Engineered specifically for Danfoss electronic controllers EKC 202 and EKC 204
    • Device Weight: Net weight is roughly 0.01 kg (0.35 oz), gross weight 0.02 kg (0.70 oz)
    • Regulatory Approvals: CE and CMIM certified
    • Product Specifications: * Type: EKA 179A Communication Module. * Interface: LON RS485. * Compatibility: EKC 202, EKC 204. * Functi…

    DANFOSS 084B8565 EKA179A Data Communication Module (EKA 179 Series).

  • DANFOSS 084B8571 EKA178B Modbus Communication Module (EKA 178 Series)

    DANFOSS 084B8571 EKA178B Modbus Communication Module (EKA 178 Series)

    REQUEST A QUOTE

    • Manufacturer: Danfoss
    • Part Number (Code): 084B8571
    • Type Designation: EKA 178B
    • Communication Protocol: Modbus (RS-485 standard)
    • Function: Data communication module / plug-in card
    • Environmental Safety: PFAS-free, REACH Candidate List substance-free
    • EKC Series: Compatible with EKC 300 and EKC 500 refrigeration regulators.
    • AK-CC Series: Compatible with case controllers such as the AK-CC 350, AK-CC 450, and AK-CC 550 series.
    • Centralized Building Management Systems (BMS): Linking commercial food displays, cold rooms, or industrial chillers to a master control room.
    • Remote Performance Monitoring: Transmitting vital refrigeration data such as temperature logs, defrost schedules, and sensor diagnostic configurations over Modbus.

    DANFOSS 084B8571 EKA178B Modbus Communication Module (EKA 178 Series).

  • DANFOSS 084B8579 EKA175A Communication Card

    DANFOSS 084B8579 EKA175A LON Communication Module (EKA 175 Series)

    REQUEST A QUOTE

    • Manufacturer: Danfoss
    • Part Number (MPN): 084B8579
    • Type Designation: EKA 175 / EKA 175A
    • Interface / Protocol: LON-module, RS-485
    • Identical Product ID: 084B8679
    • Standards & Approvals: CE, CMIM, UR
    • Net Weight: 0.01 kg (0.35 oz)

    DANFOSS 084B8579 EKA175A LON Communication Module (EKA 175 Series).

  • KEYENCE KV-XLE02 Industrial Switch

    KEYENCE KV-XLE02 Ethernet Expansion Unit (KV Series)

    REQUEST A QUOTE

    • Model Type: Ethernet Communication Unit (2 Ports)
    • Compatible CPUs: KV-X Series, KV-8000A
    • Connection Interface: RJ-45 8-pole modular connector × 2 ports
    • Transmission Rates: 10BASE-T (10 Mbps), 100BASE-TX (100 Mbps), 1000BASE-T (1000 Mbps)
    • Data Refresh Modes: Automatic refresh, Direct refresh
    • Configuration Software: Configured via KV Studio and PROTOCOL STUDIO
    • Industrial Protocols: EtherNet/IP™, PROFINET, EtherCAT® (fixed at 100 Mbps), CC-Link IE Field™ (fixed at 1000 Mbps), Modbus/TCP (Server), MC protocol / SLMP.
    • General Purpose / IT Functions: KV socket communication, PLC link, FTP Server/Client, E-mail sending/receiving, and KEYENCE sensor networks.
    • Network Restriction: Note that certain protocol modes have fixed speeds; for instance, EtherCAT cannot be mixed with general-purpose socket communications on the same infrastructure if transmission rate restrictions conflict.
    • PROTOCOL STUDIO Integration: By using KEYENCE’s native software environment, communication settings for secondary devices (like vision systems or barcode readers) are pre-registered. Implementing this expands the default command configuration from 160 standard commands up to 320 extended commands.

    KEYENCE KV-XLE02 Ethernet Expansion Unit (KV Series).